ES coincided with onset of aortic valve closure in ten of 12 subj

ES coincided with onset of aortic valve closure in ten of 12 subjects; complete closure occurred 1 frame later. The tricuspid valve began to open 1-2 frames after ES, and completely opened

2-4 frames after ES. RV volume was unchanged between ES and the frame following. However, ES volume differed significantly from volume measured 1 or 2 frames before AZD9291 supplier ES and from volume measured 2 or 3 frames following ES, although these volume differences lay within the range of observer variability. The time of minimum RV area in the 4-chamber view agreed closely with that of ES (intraclass correlation coefficient = 0.962). We conclude that minimum RV area in the 4-chamber view is a convenient buy BKM120 marker of use for ES, and that aortic valve closure or onset of tricuspid valve opening could also be used, being unlikely to result in clinically significant errors.”
“Optical microscopy allows a magnified view of the sample while decreasing the depth of focus. Although the acquired images from limited depth of field have both blurred and focused regions, they can provide depth information. The technique to estimate the depth and 3D shape of an object from the images of the same sample obtained at different focus settings

is called shape from focus (SFF). In SFF, the measure of focus-sharpness-is the crucial part for final

3D shape estimation. The conventional methods G418 purchase compute sharpness by applying focus measure operator on each 2D image frame of the image sequence. However, such methods do not reflect the accurate focus levels in an image because the focus levels for curved objects require information from neighboring pixels in the adjacent frames too. To address this issue, we propose a new method based on focus adjustment which takes the values of the neighboring pixels from the adjacent image frames that have approximately the same initial depth as of the center pixel and then it readjusts the center value accordingly. Experiments were conducted on synthetic and microscopic objects, and the results show that the proposed technique generates better shape and takes less computation time in comparison with previous SFF methods based on focused image surface (FIS) and dynamic programming. Microsc. Res. Tech. 72:362-370, 2009. (C) 2008 Wiley-Liss.Inc.”
“Background : After pneumonia, cancer involving the pleura is the leading cause of exudative pleural effusion. Cytologic examination of pleural effusions is an important initial step in management of malignant effusions. The aim of this study is to evaluate the spectrum of uncommon malignant pleural effusions in a chest disease center in Turkey.

Comments are closed.